the complete lining system. Integra Light Weight Concrete Intertenancy System can be used as an internal wall surface lining where permitted by NZBC

get price

Integra Lightweight Concrete Intertenancy System BRANZ

Dec 01, 2018  The Integra Lightweight Concrete Intertenancy System achieves a fire resistance rating (FRR) of 120/120/120 and a sound transmission class (STC) of up to 67. The

get price

Integra Light Weight Concrete Intertenancy System ...

Nov 07, 2019  BRANZ Limited Information type BRANZ Appraisal Format PDF. Description. The Integra Light Weight Concrete Intertenancy System is a sound insulating and fire-rated

get price

Lightweight Concrete Intertenancy System Now BRANZ ...

The system has passed rigorous independent acoustic and fire testing to exceed the requirements of the building code. Enjoy the benefits of the BRANZ appraised

get price

Integra Light Weight Concrete Façade System BRANZ

Jan 10, 2001  The Integra Light Weight Concrete Façade System is a pressure-moderated, cavity-based external wall cladding system for residential and light commercial type

get price

INTEGRA LIGHTWEIGHT CONCRETE INTERTENANCY SYSTEM

INTEGRA Lightweight Concrete Intertenancy System Page 8 6. Scope of use for the INTEGRA Lightweight Concrete Intertenancy System INTEGRA Lightweight

get price

Intertenancy Barrier Systems for Terrace Homes

3.1 In the opinion of BRANZ, GIB® Intertenancy Barrier Systems for Terrace Homes, if designed, used, installed and maintained in accordance with the statements and

get price

Concrete basics BRANZ Build

Apr 01, 2011  Hardened concrete has a typical compressive strength of 20–60 MPa, meaning it is resistant to directly applied loads. For example, a slender column of concrete 5 cm

get price

PARTIWALL® INTERTENANCY WALL SYSTEMS

7.1 USG Boral Partiwall® Intertenancy Wall Systems are based around a central Shaftliner™ and Firestop® fire barrier with insulated timber framed walls either side

get price

BRANZ Appraisals Product - KOROK Building Systems NZ Ltd

2.4 The KOROK® 51 mm Wall Systems have been appraised for use in intertenancy walls when used with the wall framing, wall insulation and wall lining specified in

get price

WEIGHT CONCRETE INTERTENANCY SYSTEM BRANZ

the complete lining system. Integra Light Weight Concrete Intertenancy System can be used as an internal wall surface lining where permitted by NZBC Performance Clause C3.4 (a). 12.2 The Integra Light Weight Concrete Intertenancy System achieves a Fire Resistance Rating of 120/120/120 when constructed in accordance with the Technical Literature.

get price

Integra Lightweight Concrete Intertenancy System BRANZ

Dec 01, 2018  The Integra Lightweight Concrete Intertenancy System is a sound insulating and fire-rated wall system. The Integra Lightweight Concrete Intertenancy System achieves a fire resistance rating (FRR) of 120/120/120 and a sound transmission class (STC) of up to 67.

get price

Integra Light Weight Concrete Intertenancy System ...

Nov 07, 2019  BRANZ Limited Information type BRANZ Appraisal Format PDF. Description. The Integra Light Weight Concrete Intertenancy System is a sound insulating and fire-rated wall system. The Integra Light Weight Concrete Intertenancy System achieves a fire resistance rating (FRR) of 120/120/120 and a Sound Transmission Class (STC) of up to 67.

get price

Lightweight Concrete Intertenancy System Now BRANZ ...

The system has passed rigorous independent acoustic and fire testing to exceed the requirements of the building code. Enjoy the benefits of the BRANZ appraised, tested, and trusted INTEGRA barrier intertenancy walling system for future projects. Features: All-weather construction.

get price

Integra Light Weight Concrete Façade System BRANZ

Jan 10, 2001  The Integra Light Weight Concrete Façade System is a pressure-moderated, cavity-based external wall cladding system for residential and light commercial type buildings where domestic construction techniques are used. The system consists of autoclaved aerated concrete (AAC) panels (Integra panels) fixed over high-density polystyrene or timber ...

get price

INTEGRA LIGHTWEIGHT CONCRETE INTERTENANCY SYSTEM

INTEGRA Lightweight Concrete Intertenancy System Page 8 6. Scope of use for the INTEGRA Lightweight Concrete Intertenancy System INTEGRA Lightweight Concrete Intertenancy System can be used: - • Where a Fire Resistance Rating up to 120/120/120 is required. • Where a minimum STC of at least 55 is re quired

get price

Intertenancy Barrier Systems for Terrace Homes

3.1 In the opinion of BRANZ, GIB® Intertenancy Barrier Systems for Terrace Homes, if designed, used, installed and maintained in accordance with the statements and conditions of this Appraisal, will meet the following provisions of the NZBC: Clause B1 STRUCTURE: Performance B1.3.1, B1.3.2 and B1.3.4. GIB® Intertenancy Barrier Systems

get price

PARTIWALL® INTERTENANCY WALL SYSTEMS

7.1 USG Boral Partiwall® Intertenancy Wall Systems are based around a central Shaftliner™ and Firestop® fire barrier with insulated timber framed walls either side which are lined with USG Boral Plasterboards. 7.2 USG Boral Partiwall® Intertenancy Wall Systems provide fire resistance ratings (FRRs) of 60/60/60 and 90/90/90.

get price

BRANZ Appraisals Product - KOROK Building Systems NZ Ltd

2.4 The KOROK® 51 mm Wall Systems have been appraised for use in intertenancy walls when used with the wall framing, wall insulation and wall lining specified in this Appraisal. Building Regulations New Zealand Building Code (NZBC) 3.1 In the opinion of BRANZ, the KOROK® 51 mm Wall Systems, if designed, installed, used and

get price

KOROK® INTERTENANCY APARTMENTS SYSTEMS

The KOROK® Systems meet the requirements for loads arising from self-weight, earthquake, wind, impact and creep and shrinkage. NZBC Clause B2 – Durability Under normal conditions of dry internal use KOROK® Intertenancy Systems have a serviceable life in excess of 50 years and satisfy the requirements of NZBC Clause B2 – Durability.

get price

TRIBOARD INTER-TENANCY WALL SYSTEM BRANZ

¬ Triboard houses as defined by BRANZ Appraisal No. 481 (2013); or, ¬ specifically designed timber structures designed in accordance with NZS 3603; or, ¬ specifically designed concrete framed structures designed in accordance with NZS 3101. 7.2 Triboard wall panels must be finished directly with a paint system, or for alternative finishes the

get price

5171GI GIB® INTERTENANCY BARRIER SYSTEMS

Intertenancy Barrier System for Terrace Homes - Specification and Installation Manual, dated 2016'. ... BRANZ Appraisal 928 GIB EzyBrace® Systems BRANZ Appraisal 940 GIB® Intertenancy Barrier Systems for Terrace Homes ... Expansion anchor 40mm x 6mm Fixing metal components to concrete Refer to 5113G GIB® PLASTERBOARD LININGS section and GIB ...

get price

Terrace Home Guide - GIB

INTERTENANCY SYSTEM WEIGHT The mass of intertenancy walls is an important consideration for designers and structural engineers. Weight can impact on safety requirements and foundation design, particularly in seismic areas. GIB® WARRANTY The builder is under a Building Act obligation to pass the warranty information on to the client at the end of

get price

BRANZ Appraisals Product

¬ Refer to BRANZ Appraisal No. 940 (2016) for full details of components for the GIB® Intertenancy Barrier Systems for Terrace Homes. Jointing Compounds and Tape ¬ As specified in the GIB® Site Guide Technical Literature. 4.2 System components and accessories for GIB® Noise Control Systems, which are supplied by the building contractor are:

get price

WEIGHT CONCRETE INTERTENANCY SYSTEM BRANZ

the complete lining system. Integra Light Weight Concrete Intertenancy System can be used as an internal wall surface lining where permitted by NZBC Performance Clause C3.4 (a). 12.2 The Integra Light Weight Concrete Intertenancy System achieves a Fire Resistance Rating of 120/120/120 when constructed in accordance with the Technical Literature.

get price

Integra Lightweight Concrete Intertenancy System BRANZ

Dec 01, 2018  The Integra Lightweight Concrete Intertenancy System is a sound insulating and fire-rated wall system. The Integra Lightweight Concrete Intertenancy System achieves a fire resistance rating (FRR) of 120/120/120 and a sound transmission class (STC) of up to 67.

get price

Integra Light Weight Concrete Intertenancy System ...

Nov 07, 2019  BRANZ Limited Information type BRANZ Appraisal Format PDF. Description. The Integra Light Weight Concrete Intertenancy System is a sound insulating and fire-rated wall system. The Integra Light Weight Concrete Intertenancy System achieves a fire resistance rating (FRR) of 120/120/120 and a Sound Transmission Class (STC) of up to 67.

get price

Lightweight Concrete Intertenancy System Now BRANZ ...

The system has passed rigorous independent acoustic and fire testing to exceed the requirements of the building code. Enjoy the benefits of the BRANZ appraised, tested, and trusted INTEGRA barrier intertenancy walling system for future projects. Features: All-weather construction.

get price

Integra Light Weight Concrete Façade System BRANZ

Jan 10, 2001  The Integra Light Weight Concrete Façade System is a pressure-moderated, cavity-based external wall cladding system for residential and light commercial type buildings where domestic construction techniques are used. The system consists of autoclaved aerated concrete (AAC) panels (Integra panels) fixed over high-density polystyrene or timber ...

get price

INTEGRA LIGHTWEIGHT CONCRETE INTERTENANCY SYSTEM

INTEGRA Lightweight Concrete Intertenancy System Page 8 6. Scope of use for the INTEGRA Lightweight Concrete Intertenancy System INTEGRA Lightweight Concrete Intertenancy System can be used: - • Where a Fire Resistance Rating up to 120/120/120 is required. • Where a minimum STC of at least 55 is re quired

get price

Intertenancy Barrier Systems for Terrace Homes

3.1 In the opinion of BRANZ, GIB® Intertenancy Barrier Systems for Terrace Homes, if designed, used, installed and maintained in accordance with the statements and conditions of this Appraisal, will meet the following provisions of the NZBC: Clause B1 STRUCTURE: Performance B1.3.1, B1.3.2 and B1.3.4. GIB® Intertenancy Barrier Systems

get price

PARTIWALL® INTERTENANCY WALL SYSTEMS

7.1 USG Boral Partiwall® Intertenancy Wall Systems are based around a central Shaftliner™ and Firestop® fire barrier with insulated timber framed walls either side which are lined with USG Boral Plasterboards. 7.2 USG Boral Partiwall® Intertenancy Wall Systems provide fire resistance ratings (FRRs) of 60/60/60 and 90/90/90.

get price

BRANZ Appraisals Product - KOROK Building Systems NZ Ltd

2.4 The KOROK® 51 mm Wall Systems have been appraised for use in intertenancy walls when used with the wall framing, wall insulation and wall lining specified in this Appraisal. Building Regulations New Zealand Building Code (NZBC) 3.1 In the opinion of BRANZ, the KOROK® 51 mm Wall Systems, if designed, installed, used and

get price

KOROK® INTERTENANCY APARTMENTS SYSTEMS

The KOROK® Systems meet the requirements for loads arising from self-weight, earthquake, wind, impact and creep and shrinkage. NZBC Clause B2 – Durability Under normal conditions of dry internal use KOROK® Intertenancy Systems have a serviceable life in excess of 50 years and satisfy the requirements of NZBC Clause B2 – Durability.

get price

TRIBOARD INTER-TENANCY WALL SYSTEM BRANZ

¬ Triboard houses as defined by BRANZ Appraisal No. 481 (2013); or, ¬ specifically designed timber structures designed in accordance with NZS 3603; or, ¬ specifically designed concrete framed structures designed in accordance with NZS 3101. 7.2 Triboard wall panels must be finished directly with a paint system, or for alternative finishes the

get price

5171GI GIB® INTERTENANCY BARRIER SYSTEMS

Intertenancy Barrier System for Terrace Homes - Specification and Installation Manual, dated 2016'. ... BRANZ Appraisal 928 GIB EzyBrace® Systems BRANZ Appraisal 940 GIB® Intertenancy Barrier Systems for Terrace Homes ... Expansion anchor 40mm x 6mm Fixing metal components to concrete Refer to 5113G GIB® PLASTERBOARD LININGS section and GIB ...

get price

Terrace Home Guide - GIB

INTERTENANCY SYSTEM WEIGHT The mass of intertenancy walls is an important consideration for designers and structural engineers. Weight can impact on safety requirements and foundation design, particularly in seismic areas. GIB® WARRANTY The builder is under a Building Act obligation to pass the warranty information on to the client at the end of

get price

BRANZ Appraisals Product

¬ Refer to BRANZ Appraisal No. 940 (2016) for full details of components for the GIB® Intertenancy Barrier Systems for Terrace Homes. Jointing Compounds and Tape ¬ As specified in the GIB® Site Guide Technical Literature. 4.2 System components and accessories for GIB® Noise Control Systems, which are supplied by the building contractor are: